Показати скорочений опис матеріалу
dc.contributor.author | Баязитов, Н. Р. | ru |
dc.contributor.author | Ляшенко, А. В. | ru |
dc.contributor.author | Биднюк, Е. А. | ru |
dc.contributor.author | Годлевский, Л. С. | ru |
dc.contributor.author | Коболев, Е. В. | ru |
dc.contributor.author | Bayazitov, N. R. | en |
dc.contributor.author | Lyashenko, A. V. | en |
dc.contributor.author | Bidnyuk, E. A. | en |
dc.contributor.author | Godlevsky, L. S. | en |
dc.contributor.author | Kobolev, E. V. | en |
dc.date.accessioned | 2018-02-28T13:25:42Z | |
dc.date.available | 2018-02-28T13:25:42Z | |
dc.date.issued | 2013 | |
dc.identifier.citation | Цветовые характеристики изображений, получаемых при применении лапароскопов различного диаметра, в корректной миниинвазивной диагностике / Н. Р. Баязитов, А. В. Ляшенко, Е. А. Биднюк [та ін.] // Досягнення біології та медицини. - 2013. - № 1. - С. 61-66. | ru |
dc.identifier.uri | http://repo.odmu.edu.ua:80/xmlui/handle/123456789/2569 | |
dc.description.abstract | В исследовании проведен анализ цвета лапароскопических и минилапароскопических изображений с применением теста GretagMacbeth ColorChecker Chart. Установлено, что цветопередача с расстояния к рассматриваемой поверхности в 1,5–6,5 см при применении лапароскопа минимального диаметра (2,0 мм) в 1,75 и 1,47 раза менее эффективна, чем при применении лапароскопов диаметром 10,0 и 5,0 мм. Нарушение информационных характеристик лапароскопических изображений, связанных с передачей цвета, в 83,3 % оценены как имеющие значение для ложноотрицательной диагностики как при минилапароскопическом, так и при традиционном лапароскопическом исследовании брюшной полости. В то же время ложноположительные диагнозы при минилапароскопической диагностике вдвое чаще (33,3 %) имели связь с некорректной цветопередачей. | uk_UA |
dc.description.abstract | The analysis of the color of laparoscopic and minilaparoscopic images was made using “GretagMacbeth ColorChecker Chart” test. It was established that effectiveness of color reproduction via optic system of laparoscope with minimal diameter (2.0 mm) is 1.75 and 1.47 times less when compared with similar characteristics of optical systems of laparoscopes with grater diameter (10.0 mm and 5.0 mm correspondently). In 83.3 % cases of both laparoscopic and minilaparoscopic false positive diagnoses color-deteriorated worsening of informativity of laparoscopic images have been recognized as responsible for the generation of not-corrected diagnostics of abdominal pathology. False-positive minilaparoscopic diagnoses have linked with deteriorated color reproduction two times more frequently when compared with laparoscopic false-positive diagnoses. | en |
dc.publisher | ОНМедУ | ru |
dc.subject | информативность медицинского изображения | ru |
dc.subject | лапароскопическое изображение | ru |
dc.subject | минилапароскопическое изображение | ru |
dc.subject | цвет изображения | ru |
dc.subject | ложноположительный и ложноотрицательный диагноз | ru |
dc.subject | informativity of medical image | en |
dc.subject | laparoscopic image | en |
dc.subject | minilaparoscopic image | en |
dc.subject | color characteristics of images | en |
dc.subject | false-positive and false-negative diagnoses | en |
dc.title | Цветовые характеристики изображений, получаемых при применении лапароскопов различного диаметра, в корректной миниинвазивной диагностике | ru |
dc.title.alternative | Color characterisctics of images, which are gained with laparoscops with different diameters, for correct miniinvasive diagnosis | en |
dc.type | Article | en |